====== SoftPLC OPC - release notes ====== ==== 2009.12.09 (v 0.9.9.1209) ==== * BUG-FIX: SocketClient BufferedStream timeouts are set properly ==== 2009.11.09 (v 0.9.9.1109) ==== * CHANGE: Log messages reduced ==== 2009.11.04 (v 0.9.9.1104) ==== * CHANGE: TPG structure creation uses TPGItem's Int64Value instead of DoubleValue ==== 2009.01.23 (v 0.9.9.0123) ==== * BUG-FIX: Socket client exception during connecting didn't cause Bad quality ==== 2008.11.20 (v 0.9.8.1120) ==== * CHANGE: Not so aggressive reconnection (no repeats (there were 4)) and reconnect only after 1 minute (there was 30s). ==== 2008.11.11 (v 0.9.8.1111) ==== * BUG-FIX: Short TPG format (used with Citect SCADA). ==== 2008.10.06 (v 0.9.8.1006) ==== * NEW: Short TPG format (used with Citect SCADA). ==== 2008.09.15 (v 0.9.8.0915) ==== * CHANGE: Special events in TPG. ==== 2008.07.23 (v 0.9.8.0723) ==== * CAHNGE: Changes in DataAccess module. ==== 2008.06.17 (v 0.9.8.0617) ==== * NEW: "Create typed fake values" setting added. OPC server can create typed fake values when not connected to softPLC runtime. ==== 2008.04.09 (v 0.9.8.0409) ==== * BUG-FIX: [#652] Values are correctly set even when the connection is broken at the time of request. The values are stored and set as soon as the connection is reestablished. ==== 2007.09.18 (v 0.9.7.0918) ==== * CHANGE: Common client configurator improved. No new features or bugfixes for the OPC server itself. ==== 2007.05.22 (v 0.9.7.0522) ==== * CHANGE: Release Notes.txt added to the installer. ==== 2007.02.16 (v 0.9.7.0216) ==== * BUG-FIX: [#324] The OPC config tool changed its working directory and saved the config file to incorrect directory in case that OPCDEF file was selected using file open dialog. The OPC server did not know about the changes and did not reflect them in its behaviour. ==== 2007.02.02 (v 0.9.7.0202) ==== * NEW: OPC server version is visible in the Help/About menu of the configurator. ==== 2007.01.10 (v 0.9.7.0110) ==== * BUG-FIX: [#175] More connections under OPC doesn't work. Only the first one is taken into account. * BUG-FIX: [#172] Further work on inconsistencies between Vision and SoftPLC. ==== 2007.01.08 ==== * BUG-FIX: [#172] Inconsistencies between RC Vision and SoftPLC under certain circumstances solved. * NEW: New configuration tool. * MiniPLC support. * Any character or string can be used as a level separator in the OPC name tree. ==== 2006.11.21 ==== * BUG-FIX: [#65] The server doesn't stop in case that the connection can't be established. Then it shows an error message. ==== 2006.11.04 ==== * NEW: configuration file * support for platforms (mainly because of MiniPLC) * better tweaking of the OPC server * NEW: Configurable branch separator * because of Citect compatibility request ==== 2006.06.23 ==== * soft_plc_opc.config introduced - servers as a OPC definition file instead of application config * Config file editor (ESG.SoftPLC.OPC.Config.exe) - serves for easy